Reference new model
YUYAN / Mobile light tower
New machinery / REPRESENTATIVE MODELS
See representative mobile light tower models, equipment photos, and reference technical data. Tell us your budget and destination port so we can match the right equipment solution for you.

NEW / MODEL SELECTION
Tell us your target configuration, working conditions, budget and destination; we will suggest suitable options. Configuration, supply terms and timing are set out in the written quotation.
Photos and specifications can be used to compare models; the final equipment, configuration and quotation are confirmed item by item after you contact us.
Reference new model
YUYAN / Mobile light tower
Reference new model
YUYAN / Mobile light tower
Reference new model
YUYAN / Mobile light tower
Reference new model
YUYAN / Mobile light tower
Reference new model
YUYAN / Mobile light tower
Reference new model
YUYAN / Mobile light tower
Reference new model
YUYAN / Mobile light tower
BEFORE YOU BUY / BUYING GUIDE
Price and model differences for new mobile light towers mainly come from the luminaire scheme, the mast lifting method and the genset configuration. Night road works, municipal emergency repairs and farm operations have different needs for light direction, relocation and refuelling; use the luminous flux, height and endurance data for the models on this page to prepare a more accurate inquiry.
| Model | Luminous flux | Lifting height | Continuous running time | Price |
|---|---|---|---|---|
| YUYAN BMA4000 Trailer Light Tower, Manual Mast | 440000 lm | 7/9 m | 28 h | Request quote |
| YUYAN BMN4000 Trailer Light Tower, Manual Mast | 440000 / 208000 lm | 9 m | 65 h | Request quote |
| YUYAN BMNVH1600 Trailer Light Tower, Electric Mast | 360000 lm | 9 m | 60 h | Request quote |
| YUYAN BMNVP4000 Trailer Light Tower, Manual Mast | 440000 lm | 9 m | 65 h | Request quote |
| YUYAN BMN4000B Trailer Light Tower, Manual Mast | 140000 lm | 9 m | 65 h | Request quote |
The table lists YUYAN-brand new equipment, supplied directly by YUYAN; the values are taken from the spec sheets for the corresponding models on this site. Slashes separate configurations shown in the spec sheets and are not free combinations; confirm which luminaire, genset and test conditions correspond to the luminous flux and the continuous running time.
BMNVH1600 is fitted with LED: 4×400 W fixtures and 360000 lm luminous flux; the BMN4000B spec lists LED: 21×48 W and 140000 lm. As a contractor, specify the work area, obstructions and lighting direction; rental companies should also consider ease of adjustment and component replacement. Luminous flux is not ground illuminance and cannot be used directly as covered area.
The BMA4000 spec shows 60 Hz, 230 V; the BMLV series show 50 Hz, 220 V. Match these to the power requirements at the site rather than choosing by country name alone. The BMN4000 lists continuous run time as 65 h and the BMNVH1600 as 60 h; when comparing, confirm the corresponding load and fuel-tank conditions. Datasheet run-time values are not a guaranteed autonomy for all operating conditions.
BMLV400 / BMLV1000 / BMLV500 are manually pushable; the spec lists telescopic mast heights of 1700–4800 / 1800–4500 mm, so confirm the exact variant. BMNVH1600 has electric lift with a maximum height of 9 m. For municipal repairs and farms, consider access routes, space for deploying stabilizers, ground bearing capacity and wind conditions — a taller mast should not be the only selection criterion.
BMNVH1600 dimensions (L×W×H) are 2450×1350×2650 mm, weight 860 kg; BMN4000B are 3300×2400×2000 mm, weight 1100 kg. Confirm container loading method using the collapsed dimensions and total packaged weight; check the tow bar, tires and lashing points. A towable tower does not mean it can be driven directly on your local public roads.
Not necessarily. Beam distribution, mounting height, orientation and on-site obstructions all affect actual illumination. Provide a site sketch and your lighting objectives, and check the lighting data for the selected configuration; do not determine tower count or coverage based only on luminous flux.
That is a reference running time in the model data, not a site endurance guarantee. When requesting a quote, confirm the test load, fuel-tank condition and the supplied generating set. If you will power external equipment, separately confirm available output and run time, and schedule shifts according to your refueling arrangements.
Check filters, lubricants and maintenance instructions by engine model; for water-cooled units also confirm cooling-system maintenance. Verify lamps and ballasts or LED drivers by light type, and request a spare-parts list. Winch, wire rope or electric mast mechanisms require inspection and lubrication instructions matched to the actual design.
Send the lighting scenario, desired configuration, quantity and destination port, and specify the Incoterm and any included spare parts. Lamps, the power unit, quantity and supply arrangements are confirmed in the written quotation. YUYAN can assist with documents, customs clearance and local import requirements, but your local customs broker must confirm which requirements apply.
NEXT STEP / Next step
Provide the project conditions, tonnage, budget and destination port; we will recommend a suitable configuration. Supply terms and timing are set out in the written quotation.
Inquire about this equipment ↗View verification methods ↗